Prescriptive
Meet the listed insulation R-values, window U-factors, and other requirements for each component, using any applicable exceptions. It is the straightforward checklist approach.

THE ENVIRO-FOAM RESOURCE CENTER
Practical answers for a warmer, more efficient space. From your first idea to the details behind the drywall.
01 / START WITH YOUR LOCATION
Residential guidance for the Upper Peninsula and Wisconsin. Choose where you’re building.
SOURCE CHECK: NOVEMBER 14, 2026 · Read the dated status before relying on a code edition.
LARA currently identifies the adopted 2015 residential framework as remaining in effect while the court’s order prevents implementation of the proposed 2021 residential and residential-energy rules. The August 27, 2025 order stayed the planned August 29 effective date until further court order.
Michigan’s commercial energy code has a separate adoption history. A commercial building needs its own review.
SPS 322 contains the residential energy provisions. DSPS lists the SPS 320–325 update, SS 011-25, as “Drafting Rule.” Draft July 23, 2026 council minutes in the November 11 meeting packet recommend the 2024 IRC with Wisconsin modifications as the starting point for drafting.
This is rulemaking, not an adopted replacement. Current SPS 320–325, including SPS 322, remain the applicable framework. No replacement effective date was verified in the official sources checked November 14, 2026.
Michigan’s adopted county table applies. The Upper Peninsula spans two zones.
6A: Alger, Delta, Dickinson, Marquette, Menominee.
7: Baraga, Chippewa, Gogebic, Houghton, Iron, Keweenaw, Luce, Mackinac, Ontonagon, Schoolcraft.
Zone 2: Ashland, Bayfield, Burnett, Douglas, Florence, Forest, Iron, Langlade, Lincoln, Oneida, Price, Sawyer, Taylor, Vilas, Washburn.
Zone 1: All other Wisconsin counties, including Marinette and Oconto.
MICHIGAN / ZONE 6A
Selected insulation components for new residential work. Your approved compliance path and assembly details control.
| Component | Insulation R-value |
|---|
“13 + 5” means cavity insulation plus a separate insulating layer. A slash indicates alternatives, not addition. Floor and foundation exceptions and other approved paths may apply.
Michigan tables N1101.10 and N1102.1.1Use this guide to plan questions, not to certify a design. Permit timing, building type, existing conditions, equipment, and the selected compliance method can change the requirements. Confirm the project’s path with the local building department.
BEFORE YOU CHOOSE AN R-VALUE
Start with the building’s actual use, what you’re changing, and whether the space will be heated or cooled. Then choose an accepted way to demonstrate compliance.
Meet the listed insulation R-values, window U-factors, and other requirements for each component, using any applicable exceptions. It is the straightforward checklist approach.
A total-UA calculation compares heat loss through the complete enclosure. Better windows or another better-insulated component may offset a weaker one within the rules. This is not a furnace-efficiency trade-off.
Approved software compares the proposed design with a code-defined reference building. The report must satisfy the adopted method and match the work installed. Mandatory provisions and other safety requirements still apply.
You must meet the applicable energy code, but an approved alternative can allow a design that differs from individual prescriptive R-values. Spray foam’s air sealing does not, by itself, authorize a lower R-value.
ICC explanation of residential paths · DOE: total-UA / REScheck · Wisconsin SPS 322.31 and 322.50–53
02 / THE DETAILS PEOPLE ASK ABOUT
These are specific exceptions with conditions. A low roof or a vaulted ceiling does not automatically qualify.
The standard prescriptive ceiling value in the U.P. and Wisconsin. More insulation can be a design choice; the minimum is not an energy-savings guarantee.
Michigan permits R-38 across the entire ceiling area requiring insulation when full, uncompressed R-38 also extends over the exterior-wall top plates at the eaves.
Wisconsin permits R-38 where its full, uncompressed depth extends over the exterior-wall top plates at the eaves.
A thin or compressed edge does not meet this condition.
A ceiling without attic space may qualify when the assembly cannot fit the otherwise-required insulation.
Michigan: no more than 500 sq ft or 20% of the total insulated ceiling area, whichever is smaller.
Wisconsin: up to 500 sq ft. Its rule does not use Michigan’s 20% limit.
TRY THE AREA LIMIT
This checks area only. The assembly still must qualify, and required ventilation space must be preserved.
MICHIGAN SELECTEDChange stateMichigan: N1102.2.1–2 / R402.2.1–2. These reductions do not apply to the U-factor or total-UA alternatives. State-code summary from Otsego County (PDF) · 2015 IECC ceiling provisions
Wisconsin: SPS 322.31 and 322.32(1)–(2). Official energy rules (PDF)
Michigan separately provides an alteration exception for existing ceiling, wall, or floor cavities exposed during construction and filled with insulation, provided energy use is not increased. This is not the R-30 area exception and is not a blanket rule for new construction. N1101.3.1, exception 3.
For Wisconsin existing homes, scope, age, permit timing, and local adoption matter. Alterations, repairs, and older dwellings have distinct rules; a retrofit does not automatically require bringing the entire home up to new-construction standards. SPS 320.02–320.05 (PDF).
03 / TAKE THE MYSTERY OUT OF THE LANGUAGE
A few useful distinctions before you compare products or quotes.
Insulation in the spaces between studs, joists, or rafters. The framing interrupts the insulation layer. Spray foam between studs is still cavity insulation.
A layer running across structural members, with only permitted interruptions such as fasteners and service openings. It can sit inside, outside, or within an assembly.
Wood-frame walls use wood studs. Mass walls include qualifying concrete, masonry, ICF, and solid log assemblies. Brick veneer over studs does not make a mass wall.
R-value describes resistance to heat flow; higher means more resistance. U-factor describes heat transfer; lower means less. A whole wall also includes framing and other heat-flow paths.
An air barrier controls air movement. A vapor retarder limits diffusion through materials. Neither term automatically means waterproofing, and a ground vapor barrier does not fix bulk-water entry.
The boundary around heated or cooled space. In one attic it follows the ceiling; in another, the roofline. Choosing that boundary is part of designing the assembly.
A ROOM’S NAME DOESN’T SET ITS WALL REQUIREMENT
Grade is the adjacent ground level. Energy-code classification also considers how much wall area is buried and what space it encloses.
Michigan: the residential energy definition treats a wall enclosing conditioned space as a basement wall when at least half is below grade. A mostly exposed walkout wall can fall under above-grade requirements. Evaluate the relevant wall areas with the official.
Wisconsin: if less than half the total basement wall area is below grade, the entire wall area, including the buried part, counts as exterior wall area under SPS 322.32(6)(c).
“Mass wall” describes the construction; “basement wall” describes its location and enclosure role. These labels are not interchangeable.
Residential energy definitionsWisconsin basement-wall rule (PDF)04 / WHEREVER YOU ARE IN THE PROJECT
Attic planning background: DOE/PNNL vented-attic guide. Every scope is confirmed for the actual project.
Use the prescriptive values when that is the project’s approved compliance method and no specific exception applies. New conditioned construction and additions generally need energy-code compliance. An accepted total-UA or performance design may use different component values; it needs the required calculations and approval, not just a contractor’s opinion. Compare the three approaches.
Michigan: use Michigan’s amended requirements and accepted compliance documentation. The residential code also provides a separate Energy Rating Index route. Michigan energy provisions, N1105–N1106.
Wisconsin: SPS 322 provides prescriptive, total-UA, and simulated-performance options for covered one- and two-family dwellings. Requirements still apply unless that method specifically exempts them. SPS 322.02, 322.31 and 322.50–53.
Michigan: an alteration generally brings the work being changed into compliance without requiring untouched portions of the house to meet new-construction standards. Specific exceptions include existing exposed ceiling, wall, or floor cavities filled with insulation, and work where existing cavities remain unexposed, provided building energy use is not increased. These are alteration exceptions—not permission to underinsulate a new addition. N1101.3.1 and its exceptions.
Wisconsin: additions and alterations to covered dwellings follow the code applicable to the project; true repairs and maintenance have a separate exemption. Building age and local adoption matter. Chapter 322 energy rules began December 1, 1978; other UDC chapters began June 1, 1980. Older dwellings may be exempt under the state UDC, while municipalities may adopt its requirements for their additions and alterations. “Pre-1980” alone is not a reliable answer. SPS 320.03–320.05.
Describe what will be opened, replaced, or newly enclosed when you request the permit review. An attic top-up, a stripped wall, and a converted garage can have different obligations.
Michigan: converting an unconditioned or low-energy space to conditioned space triggers the residential energy code’s change-in-conditioning requirements. Review the enclosure around the converted space, not just the surface receiving new insulation. An accepted performance route may provide flexibility. Do not assume the ordinary existing-cavity exception settles a garage, attic, or workshop conversion. DOE/PNNL explanation of the 2015 conversion provisions.
Wisconsin: a barn or garage converted to residential use must comply with the UDC. Installing heating or air conditioning in a covered dwelling also invokes Chapter 322. A limited exception exists for supplemental heat in an attached garage: a permanently limited thermostat of 50°F or less, a separate heating zone or equipment, and any separate equipment sized for no more than 50°F. This is not a general exemption for heated shops or living space. SPS 320.04 · SPS 322.30(4).
Tell us the intended temperature and use before selecting insulation. Air sealing, ventilation, moisture control, and fire protection belong in the conversion plan too.
Michigan: yes. The residential update remains stayed; LARA lists the 2015 residential framework and the separate 2021 commercial energy code, effective April 22, 2025. Also, building-code and energy-code labels do not always match: some low-rise multifamily buildings use residential energy provisions while their construction is under the Michigan Building Code. Confirm occupancy and energy-code scope before using a house insulation table. LARA code list · Michigan residential-energy scope and paths.
Wisconsin: one- and two-family dwellings use the UDC framework. Commercial buildings and larger multifamily projects need separate review under SPS 361–366 and the applicable adopted energy provisions. The updated commercial codes took effect September 1, 2025, with compliance required for plans submitted on or after November 1, 2025. Do not apply the one- and two-family table to every building that contains residences. DSPS commercial-building guidance.
For existing commercial buildings, alteration rules generally focus on the work changed; new envelope assemblies and changes in use can trigger additional requirements. 2021 IECC C503–C505.
No automatic exemption. The actual use of the building matters. Agricultural zoning and post-frame construction do not establish an exemption by themselves.
Michigan: the statutory exclusion concerns a building incidental to agricultural use of the land, provided it is not used in retail trade. A house or unrelated business on farm-zoned land does not become exempt just because of the parcel’s zoning. MCL 125.1502a(1)(g).
Wisconsin: the UDC farm-building exemption requires exclusive farm operations and no human habitation. The commercial exemption also has specific farm-premises and farming-use conditions, including limits on consumer access and farm-product sales. Retail, an event venue, a residence, or mixed use requires a fresh review. SPS 320.05(6) · DSPS farm-building explanation.
Have the building department confirm the exemption for the intended use. Zoning, electrical, plumbing, mechanical, and other applicable requirements still need their own review.
No. Condensation-control insulation and total energy-code insulation are different checks. The 2015 IRC table lists R-25 for zone 6 and R-30 for zone 7 in applicable unvented assemblies; those values do not replace total insulation requirements. Ventilation, vapor control, and the assembly’s layers still need review. IRC R806.5.
No. The studs interrupt that layer. Continuous insulation crosses the framing. The material name does not change that distinction.
Not by itself. Insulation and air sealing do different jobs. Attic penetrations, hatches, and transitions need attention along with insulation coverage. DOE attic air-sealing guide.
A ground membrane addresses ground vapor. Drainage, leaks, groundwater, humidity, and the location of the thermal boundary still need to be evaluated. A liner-only price is not a complete moisture-remediation design. DOE/PNNL foundation guidance.
The answer depends on the space, access and use, product, and tested assembly. Thermal barriers and ignition barriers have different roles. A product’s fire test is not blanket permission to leave foam exposed; the final scope must identify the required protection. Manufacturer technical documents.
No. It prices the dimensions and material level you choose. It cannot determine the approved compliance path, inspect a roof assembly, or confirm local requirements. We review those details before setting the final scope.
There is no honest universal percentage. Existing insulation, leakage, heating equipment, weather, and how you use the building all affect the outcome. Jesse is a BPI energy auditor and building analyst. Our energy audits and blower door testing can help you understand the building and prioritize improvements. DOE guide to home-energy assessments (PDF).
Send the project town, approximate dimensions, a wide view, close-ups of framing or obstructions, and the access point. Roof pitch, cavity depth, crawlspace height, piers, and known moisture issues are especially helpful. Measure only areas you can reach safely.
For a flat, vented attic, we often start with cellulose for value and coverage. Fiberglass can be preferable where ceiling weight or an approved cavity installation favors it. Closed-cell foam offers compact insulation and air control at a higher cost. Our attic material guide explains settling, weight, slopes, and air barriers.
We plan the installation using the selected product’s initial thickness and required material quantity, with its settled depth already accounted for. The goal is the labeled long-term R-value. See how settling is included.
No matching questions. Try another word, or ask Jesse about the project.
06 / WORTH A LOOK
A curated reading shelf, checked November 14, 2026. Publication, meeting, or check dates are labeled; these are not a live news feed.
The November 11 council packet includes draft July 23 minutes recommending the 2024 IRC, with Wisconsin modifications, as a drafting basis. That recommendation does not put a new code into effect.
For current projects, continue planning under the applicable SPS 320–325 rules. We have not verified a replacement effective date.
Read the council packetCheck official rule statusICC-ES reissued ESL-1372 for a specified closed-cell-foam wall assembly. It is a useful reminder to read the actual assembly conditions behind a product’s test listing.
Read the ICC-ES listingOwens Corning’s update describes a Kansas City production line planned for 2027, following its September 2025 announcement. The article does not establish future local pricing or availability.
Read the manufacturer’s updateDOE’s attic guide explains why penetrations and transitions deserve attention before new insulation hides them. A useful starting point for an attic upgrade.
Read the DOE guideIndustry links are for context, not endorsements or approval of a product for your particular building.
PUT THE INFORMATION TO WORK
Bring your questions, plans, or a few photos. We’ll help turn the details into a clear scope.
Talk to Enviro-FOAMTry the cost calculator